Dear Tess,
it looks like that you are using some experimental options. Have you changed any defaults or are you running CAt12 in developer mode? What version are you using?
Best,
Christian
On Sat, 15 Jan 2022 09:51:09 +0000, Tess Chaffey <[log in to unmask]> wrote:
>Hi all - I am trying to do some longitudinal MRI analysis for two time points using CAT12 and I keep running into the error shown below. I have no directory called "Volumes" so I am unsure why the script is making reference to this directory or how to change this. Is there anyone who has encountered a similar error and is able to shed some light on how to proceed?
>
>03-Jan-2022 12:31:54 - Done 'Run Shooting (create Templates)'
>03-Jan-2022 12:31:55 - Running 'Resize images'
>03-Jan-2022 12:31:55 - Failed 'Resize images'
>Error using spm_vol>spm_vol_hdr (line 80)
>File "/Volumes/WD4TBE2/MRData/202005 - LongShoot/mri/p0avg_deface_1007_v1_t1w.nii" does not exist.
>In file "/data/SOFTWARE/spm12/spm_vol.m" (v5958), function "spm_vol_hdr" at line 80.
>In file "/data/SOFTWARE/spm12/spm_vol.m" (v5958), function "spm_vol" at line 61.
>In file "/data/SOFTWARE/spm12/toolbox/cat12/cat_vol_resize.m" (v1648), function "cat_vol_resize" at line 78.
>
>Thanks in advance!
>
>Tess
|