Hi,
Most likely cause is that you already have an optics group
table ("data_optics") but the particle datablock does not have
a name; it must be "data_particle" not "data_".
Best regards,
Takanori Nakane
> Hi All,
> I have a question about the star handler in Relion 3.1-beta-commit-a6aaa5.
> I have got an error during import or running of refinement/classification
> jobs with a particle star file:
>
> ERROR:
> StarConverter::convert_3p0_particlesTo_3p1: Star file is already at
> version 3.0001
>
> This error happens to all my star files which were modified outside Relion
> 3.1. I used a home-made script which keeps particles only from selected
> micrographs with all metadata rows. Previously in Relion 3.0, everything
> was working perfectly fine.
>
> What is the star file check for Relion 3.1? I am wondering if the is any
> part of the star file which is recognized by jobs and tries to convert it
> to the new format of star files. Is it possible to switch this option off?
> I would be very grateful for some hints!
>
> Best,
> Dawid
>
> ########################################################################
>
> To unsubscribe from the CCPEM list, click the following link:
> https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCPEM&A=1
>
########################################################################
To unsubscribe from the CCPEM list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCPEM&A=1
|