Hi Jeongyoon,
Perhaps you could try to run relion_image_handler --stats on the
micrographs.star file (you may need to change the rlnMicrographName label
into rlnImageName for this). Just to make sure there is nothing unexpected
there..
HTH,
Sjors
> Dear all,
>
> I’m trying to perform auto-picking of 100 micrographs containing 4096
> pixels on each side and all are in the same magnification.
> I’m sure the images are in the same size, but when I ran the
> auto-picking I got these errors as attached here.
> Does anyone get the same problem as me? Or anyone could help me in this
> please?
> It seems the program tries to change the pixel size for whatever reason??
>
> Thanks a lot,
> Jeongyoon
>
> [cid:7A1B2F1B-D0D4-4F94-BE39-E11A885E5595@bioch.ox.ac.uk]
>
> ########################################################################
>
> To unsubscribe from the CCPEM list, click the following link:
> https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCPEM&A=1
>
--
Sjors Scheres