Thanks, Misun. I'll look into this.
Vladimir
On Sun, Apr 15, 2018 at 9:18 PM, Misun Kim <[log in to unmask]> wrote:
> Hi, I found that I can't load the spmeeg file created with latest SPM12 (v.7219) from previous version of SPM12 (v.6225). This seems due to change in Fieldtrip's data naming convention (see below).
> Although this is not a pure SPM issue, I want to report it here so that other users won't be puzzled like me when they face the same problem.
>
> bests,
> Misun
>
> 1.---------------SPM error message--------------
> Reference to non-existent field 'labelorg'.
>
> Error in ft_datatype_sens (line 386)
> sens.balance.G1BR.chantypeorg = repmat({'unknown'}, size(sens.balance.G1BR.labelorg));
>
> Error in ft_datatype_sens (line 146)
> sens = ft_datatype_sens(sens, 'version', '2011v2');
>
> Error in checkmeeg (line 371)
> this.sensors.meg = ft_datatype_sens(this.sensors.meg, 'version', 'upcoming', 'amplitude', 'T', 'distance', 'mm');
>
> Error in meeg (line 139)
> D = class(checkmeeg(D), 'meeg');
>
> Error in spm_eeg_load (line 73)
> D = meeg(D);
>
> 2.---------------Fieldtrip script-----------------------------
> function [sens] = ft_datatype_sens(sens, varargin)
> % Revision history:
> % (2016/latest) The chantype and chanunit have become required fields.
> % Original channel details are specified with the suffix "old" rather than "org".
> % All numeric values are represented in double precision.
> % It is possible to convert the amplitude and distance units (e.g. from T to fT and
> % from m to mm) and it is possible to express planar and axial gradiometer channels
> % either in units of amplitude or in units of amplitude/distance (i.e. proper
> % gradient).
> -----------------------------------------------------
|