Dear Vasudev,
Thank you very much for your response! In addition to the down-sampling issue, I realized that FLICA will split the dr_stage2 results into fragments, which is not what I want. So I decided not to use FLICA.
Thanks again,
Jun
> 2017/08/01 7:17、Dev vasu <[log in to unmask]> のメール:
>
> Dear Miyata,
>
> Unfortunately, it seems not many are using FLICA toolbox , and the support for any question pertaining to toolbox is hard to obtain. For your question, your can input dr_stage2 results, when i used rfMRI data for analysis , i used ICs of interest , but there will be problems pertaining to down sampling of your data. Possibly using DMN would be a better option.
>
> Thanks
> Vasudev
>
> On 11 July 2017 at 01:36, Jun Miyata <[log in to unmask]> wrote:
> Dear FSL experts,
>
> I posted the question below a week ago, but so far have no response. I would like to know if I can use FLICA for my multi-modal data of resting-state fMRI, TBSS and VBM. I appreciate your feedback.
> Thanks in advance,
>
> Jun
>
> > 2017/07/03 15:18、Jun Miyata <[log in to unmask]> のメール:
> >
> > Dear FSL experts,
> >
> > I'm wondering if I can input rsfMRI data (possibly dr_stage2 images from dual regression) into FLICA, together with FSL-VBM and TBSS data. I've searched in the archive but could not find an answer. If inputing dr_stage2 images is correct, should I use all the ICs including motion artifacts or use only the ICs of interest?
> > Thanks in advance,
> >
> > Jun
>
|