Dear Helmut,
Thanks but still a question. As far as I know, most people using svc reported peak-level FWE-corredted p value rather than cluster level data. So, if I just want to report peak-level data, for the procedures you said as below:
(1) Select your contrast, enter any threshold, be it corrected or uncorrected, this is irrelevant
(2) Define your small volume
(3) Look at the updated FWEp at the bottom up the results table, this is the critical T (or F) value for .05 FWE on peak level for the small volume
(4) Re-load the contrast, choose "none" for "p value adjustment to control", enter the T (or F) value from (3)
(5) Define your small volume like you did in (2)
can I just enter 1 (i.e., p value = 1.0) in (1) to include all voxels of the brain, then follow (2)-(5)? By doing so, I won't miss any peak. I don't care if k in the table is correct or not, because I just want to report peak-level data.
Mike
|