Dear Herman and others
I did run my data through Xtriage - it indicated no twinning but there's a moderate anisotropy. There are also ice rings but not strong. I always run Phaser in all possible SGs, so I ruled this out earlier.
When I processed my data, autoindexing from XDS/Xia2 gave me the following solutions:
oC 134.50 425.10 84.50 90.00 90.00 90.00
mC 425.10 134.50 84.50 90.00 90.10 90.00
mP 134.50 84.50 222.90 90.00 107.50 90.00
aP 84.50 134.50 222.90 107.50 90.10 90.00
Output from the CORRECT.LP file in the /integrate folder:
* 44 aP 0.0 84.5 134.5 222.9 107.6 90.0 90.0
* 31 aP 0.0 84.5 134.5 222.9 72.4 90.0 90.0
* 41 mC 0.0 425.0 134.5 84.5 90.0 90.0 90.0
* 35 mP 0.0 134.5 84.5 222.9 90.0 107.6 90.0
* 40 oC 0.0 134.5 425.0 84.5 90.0 90.0 90.0
* 30 mC 0.0 134.5 425.0 84.5 90.0 90.0 90.0
If I want to re-process the images in P1, do I use the cell parameters in the first line above, or do I use the one from lattice oC? And what is the difference from expanding into P1? If I'm not mistaken, the latter option preserves the original cell parameters (?).
Thanks.
Mohamed
|