I have a single TI 100 dynamics pCASL data which were acquired without the receiver sensitivity maps. I am using BASIL for quantification of CBF.
Here is the command line:
oxford_asl -i difference_data --tis 2.7 --bolus 1.5 --bat 1.3 --t1 1.3 --t1b 1.65 --alpha 0.85 --artoff --fixbolus --casl -s ${t1_folder}/${t1_image_MNI} --regfrom asldata_mc_even_brain
asl_calib -i ${scan_folder_asl_path}/native_space/perfusion --tissref csf --t1r 4.3 --t2r 750 --t2b 150 --te 29 -o ${scan_folder_asl_path}/calibration -m t1_reorient_brain_pve_0_asl_space_thr_0.95 -c asldata_mc_even --mode longtr --tr 4.5 --cgain 1.0
where
difference_data is control-tag
asldata_mc_even_brain is the skull stripped motion corrected asl data (mean of the even volumes)
t1_reorient_brain_pve_0_asl_space_thr_0.95 is the CSF mask obtained from T1 image thresholded at 95%
asldata_mc_even is the motion corrected asldata in native space (only the even volumes)
Are the commands right? If no, how do I modify to get M0 for calibration from CSF mask?