Dear Frederik,
It seems that the number of time-points (rows) in your par/txt file with the 6 realignment parameters is different from the number of time-points of your input fMRI data. These should correspond with each other. Can you please check this?
Best,
Raimon
________________________________________
Van: FSL - FMRIB's Software Library [[log in to unmask]] namens Frederik Bartels [[log in to unmask]]
Verzonden: maandag 8 juni 2015 19:48
Aan: [log in to unmask]
Onderwerp: [FSL] ICA-AROMA Error
Hi,
running ICA-Aroma on my data leads the following error:
------------------------------- RUNNING ICA-AROMA -------------------------------
--------------- 'ICA-based Automatic Removal Of Motion Artifacts' ---------------
Step 1) MELODIC
Step 2) Automatic classification of the components
- registering the spatial maps to MNI
- extracting the CSF & Edge fraction features
- extracting the Maximum RP correlation feature
Traceback (most recent call last):
File "ICA_AROMA.py", line 200, in <module>
maxRPcorr = aromafunc.feature_time_series(melmix, mc)
File "/media/guestuser/DATA2/ICA_AROMA_KIMSCA/ICA_AROMA_functions.py", line 238, in feature_time_series
RP_model_temp = RP_model[idx,:]
IndexError: index 257 is out of bounds for axis 0 with size 256
Can anyone help with this?
Thank you!
Frederik
|