These are two different types of completness indicators
Scalepack reports Bragg's law completness, 98.8% of your unique
reflections were in diffracting condition. If you use automatic
corrections only informative reflections are output, for anisotropic
diffraction 64% is reasonable
> Hi All,
>
> Scalepack output says 98.8% complete data but after converted to .mtz file
> it reduced to 64%.
> I have tried in CCP4 and phenix both.
> How is it possible?
>
> Ayan
>
Zbyszek Otwinowski
UT Southwestern Medical Center at Dallas
5323 Harry Hines Blvd.
Dallas, TX 75390-8816
Tel. 214-645-6385
Fax. 214-645-6353
|