Sad, no Eiger. There might be teething problems.
Richard
On 11.04.2015, at 12:03, Meitian Wang <[log in to unmask]<mailto:[log in to unmask]>> wrote:
=======================================================================
SYNCHROTRON BEAM TIME FOR MACROMOLECULAR CRYSTALLOGRAPHY AT SLS
=======================================================================
NOTE: Proposal call schedule has been changed from 3-call to 2-call per year. The current call is the first call in the new schedule.
Proposal application deadline: Wednesday, April 15, 2015
Periods:
July 1, 2015 - December 31, 2015 (Normal / Test proposals)
July 1, 2015 - June 30, 2017 (Long-term proposals)
Proposal submission:
http://www.psi.ch/sls/px-beamlines-call-for-proposals
Travel support:
http://www.psi.ch/useroffice/sls-elisa-biostruct
X06SA Beamline features (http://www.psi.ch/sls/pxi/pxi)
- Undulator beamline with flux of 2x10^12 photons/sec at 12.4 keV (1?) and fully tunable from 6.0 to 17.5 keV (2.07 - 0.71 ?)
- Focused beam size and divergency: 10x5 microns and 2.0x0.3 mrad
- Variable beam size from 5 um to 100 um
- In meso in situ serial crystallography with micro-beam and SLS PX software (DA+)
- PILATUS 6M pixel detector enabling continuous and fine phi-sliced data acquisition with 20 bit dynamic range (see http://pilatus.web.psi.ch/ or www.dectris.com<http://www.dectris.com/> for further information)
X06DA Beamline features (http://www.psi.ch/sls/pxiii/pxiii)
- Super-bending magnet beamline with flux of 5x10^1^1 photons/sec at 12.4 keV (1?) and fully tunable from 6.0 to 17.5 keV (2.07 - 0.71 ?)
- Focused beam size and divergency: 80x45 microns and 2x0.5 mrad (with possibility to reduce horizontal divergency to 0.4 mrad)
- Mini-hutch design for fast manual mounting
- PILATUS 2M (60 Hz)
- Multi-axis goniometer (PRIGO) for native-SAD phasing (T. Weinert, et al., Nature Methods, 12, 131, 2015)
- New phasing protocols with energy interleaving and multi-orientation strategy
- In-situ X-ray diffraction screening (with any SBS format plate) available during users shifts (R. Bingel-Erlenmeyer, et al., Crystal Growth & Design 11, 916, 2011)
X10SA Beamline features (http://www.psi.ch/sls/pxii/pxii)
- Undulator beamline with flux of 2x10^12 photons/sec at 12.4 keV (1?) and fully tunable from 6.0 to 20 keV (2.07 - 0.62 ?)
- Focused beam size and divergency: 50x10 microns and 0.6x0.1 mrad
- Micro-beam with apertures (10 x 10, 30 x 30 micrometer)
- PILATUS 6M pixel detector
Best regards,
The MX group at SLS
__________________________________
Meitian Wang
Swiss Light Source at Paul Scherrer Institut
CH-5232 Villigen PSI - http://www.psi.ch/sls/
Phone: +41 56 310 4175
|