Hi Dave,
Did you get the same error in a normal auto-refine as well? If so, I have
no clue what's going on. Perhaps someone else has seen this?
S
> Hi Sjors,
>
> I double-checked the _data.star files and they look ok to me. They were
> generated from the one that was output from a 3D auto-refinement using the
> shiny particles.
>
> When running I get the following print out:
>
> + Using pixel size calculated from magnification and detector pixel size
> in the input STAR file: 1.72001
> Back-projecting all images ...
>
> Then it falls over and gives the error message that I posted initially.
>
> Thanks,
>
> Dave
>
--
Sjors Scheres
MRC Laboratory of Molecular Biology
Francis Crick Avenue, Cambridge Biomedical Campus
Cambridge CB2 0QH, U.K.
tel: +44 (0)1223 267061
http://www2.mrc-lmb.cam.ac.uk/groups/scheres
|