Hi Ardan,
No. Differences may for example arise from different MTFs of the
detectors used in the EM and X-ray experiments (or other
envelope-affecting factors).
Sjors
On 10/30/2013 06:09 PM, Ardan Patwardhan wrote:
>
> Dear all
>
> I was wondering if anyone could point me to a reference on the
> following question:
>
> Is the rotationally averaged power spectrum of a 3DEM reconstruction
> (in the absence of CTF effects etc) expected to be identical to a
> small angle X-ray scattering (SAXS) curve?
>
> Many thanks and best wishes
>
> Ardan Patwardhan
>
> European Bioinformatics Institute (EMBL-EBI) European Molecular
> Biology Laboratory
>
> Wellcome Trust Genome Campus
>
> Hinxton, Cambridge CB10 1SD, UK
> Tel: +44 1223 492649
>
--
Sjors Scheres
MRC Laboratory of Molecular Biology
Francis Crick Avenue, Cambridge Biomedical Campus
Cambridge CB2 0QH, U.K.
tel: +44 (0)1223 267061
http://www2.mrc-lmb.cam.ac.uk/groups/scheres
|