Hi everyone,
I am trying to do simulation by using POSSUM MRI simulator. The parameters that I want to use are listed as below. For some reasons, these settings cannot pass the consistency check. Does anybody know the reason and help me solve it? Thanks very much for your kind help!
Object:/usr/local/fsl/data/possum/brain.nii.gz
Pulse sequence:
TE(s):0.028
TR(s): 3
TRslice: 3.0
Number of voxels: 80*80*60
Voxel Size (mm):3*3*3
k-space:100
flip angle:90
number of volumes:22
gap:0
BW(hz): 1788 (the default number is 100000, which is much bigger than my parameter. My number is used in real experiments. why there are so big difference here?)
echo spacing (s): 0.0007034 (cannot be changed in system, why?)
B0 field:
Field strength: 3T
Motion: None
Activation: T2
Noise: None
Sincerely,
Ying Wang
|