Hi all,
At Liverpool, we support the BIOMED VO. We also periodically scan the
Operations Portal Data (formerly known as the CIC Portal) to keep the
GridPP Approved VOs document up to date
(https://www.gridpp.ac.uk/wiki/GridPP_approved_VOs). I use a tool called
VomsSnooper to do this, because it is far too painstaking to do by hand.
Today, VomsSnopper has found several problems.
First, the entry for BIOMED (see below) has been changed such that no
x509 certificate is available. It is not possible to use that for the
Approved VOs document. I'll leave things as they are for the time being,
but I have to contact someone to have this fixed.
Second, some changes have happened to the VOMS Servers for Atlas. I was
surprised that I saw no notification was made about this, because Atlas
is obviously important. Did I miss it somehow (see below).
Before I escalate these problems, is there anyone in the group who can
comment, especially with regard to the Atlas changes. Is something going on?
Steve
:------- BROKEN BIOMED VOMSERVER ENTRY (no x509) ---------
<VOMSServers>
<VOMS_Server HttpsPort="8443" VomsesPort="15000" IsVomsAdminServer="1"
MembersListUrl="https://cclcgvomsli01.in2p3.fr:8443/voms/biomed/services/VOMSAdmin?method=listMembers">
<hostname>cclcgvomsli01.in2p3.fr</hostname>
</VOMS_Server>
</VOMSServers>
:------- NEW ATLAS VOMS SERVER ---------
VO_ATLAS_VOMSES=" 'atlas vo.racf.bnl.gov 15003
/DC=org/DC=doegrids/OU=Services/CN=vo.racf.bnl.gov atlas' "
VO_ATLAS_VOMS_CA_DN=" '/DC=org/DC=DOEGrids/OU=Certificate
Authorities/CN=DOEGrids CA 1' "
--
Steve Jones [log in to unmask]
System Administrator office: 220
High Energy Physics Division tel (int): 42334
Oliver Lodge Laboratory tel (ext): +44 (0)151 794 2334
University of Liverpool http://www.liv.ac.uk/physics/hep/
|