Hi Saad,
Thank you for your reply.
how to extract <b0> and <b1000> from 2 volume DWI nifty file.
I use bet to create an extracted brain image which is <b0> (1 volume)
how about <b1000> which is another volume, right?
Thank you for your time.
Bo
________________________________________
From: FSL - FMRIB's Software Library [[log in to unmask]] On Behalf Of Saad Jbabdi [[log in to unmask]]
Sent: 08 June 2012 11:57
To: [log in to unmask]
Subject: Re: [FSL] Create ADC from DWI volume
Hi Bo
Yes you can use fslmaths:
fslmaths <b0> -div <b1000> -log -div 1000 <adc_map>
Cheers
Saad
On 8 Jun 2012, at 11:25, Suchada Tantisatirapong wrote:
> Hello,
>
> I am quite confused with DWI. I have 2 volumes of DWI scanned at 0 and 1000 s/mm^2.
> Can I use FSL to reconstruct ADC map?
>
> Many thanks
> Bo
>
> ________________________________________
> From: FSL - FMRIB's Software Library [[log in to unmask]] On Behalf Of Suchada Tantisatirapong [[log in to unmask]]
> Sent: 08 June 2012 10:55
> To: [log in to unmask]
> Subject: [FSL] Create ADC from DWI volume
>
> Hello,
>
> I have dwi volumes which was scanned 2 direction 0 and 1000 s/mm^2. Can I create a ADC map from these volume by using FSL tool?
>
> Many thanks
> Bo
--
Saad Jbabdi
University of Oxford, FMRIB Centre
JR Hospital, Headington, OX3 9DU, UK
(+44)1865-222466 (fax 717)
www.fmrib.ox.ac.uk/~saad
|