Dear Panagiotis,
This is not a problem with checkmeeg but again a problem with toolbox compatibilities. You should make sure there is no other Fieldtrip version in your path when running SPM. SPM8 is not compatible with the latest changes in Fieldtrip, but SPM12 will be when it comes out.
Best,
Vladimir
On 14 Apr 2012, at 23:03, Panagiotis Tsiatsis <[log in to unmask]> wrote:
> Hello dear Vladimir,
> There might be a problem with the latest version of checkmeeg (version 4337). More specifically, when I try to read in my CTF meg continuous data (both via the .meg4 and .res4 files), I get the following error
>
> Reference to non-existent field 'pnt'.
>
> Error in checkmeeg (line 371)
> if isempty(meegstruct.sensors.eeg) || isempty(meegstruct.sensors.eeg.pnt)
>
> Error in meeg (line 108)
> [OK D] = checkmeeg(varargin{1}, 'basic');
>
> Error in spm_eeg_convert (line 427)
> D = meeg(D);
>
> Error in spm_eeg_convert_ui (line 89)
> D = spm_eeg_convert(S);
>
> Error while evaluating uicontrol Callback
>
>
> The previous version that I had, which was 4207, was working fine.
>
> Thanks and best,
> Panagiotis
>
> --
> Panagiotis S. Tsiatsis
> Max Planck Institute for Biological Cybernetics
> Cognitive NeuroImaging Group
> Tuebingen, Germany
>
|