Subject:

Re: MaxFilter (2.2.10) questions

From:

Christopher Bailey <[log in to unmask]>

Reply-To:

Christopher Bailey <[log in to unmask]>

Date:

Tue, 20 Mar 2012 11:06:19 +0100

Content-Type:

text/plain

Parts/Attachments:

Parts/Attachments

text/plain (79 lines)

Hi Jukka,

So glad to hear this wasn't trivial after all :)

I think I understand your point: the difference in -mc and -headpos output is a "feature", not a "bug". My take-home is that IF there is sudden movement, both will be equally good at detecting it. So we don't need to run headpos as a separate step to be able to reject individual trials on the basis of excessive motion, which is good.

I would certainly like to try out the utility script you mention for robust estimation of a suitable origin for the expansion. Please let me know how to get my hands on it :)

Thanks for your time,

Chris
--
Christopher Bailey, MSc
MEG Engineer, MINDLab Core Experimental Facility
Center of Functionally Integrative Neuroscience (CFIN)
Aarhus University, Denmark

tel. cell: +45-2674-9927
tel. office: +45-7846-9944

On Mar 20, 2012, at 10:00 AM, Jukka Nenonen wrote:

Hi Chris,

Congratulations for the tricky example :-) I didn't find actual bugs, but certainly some aspects can be improved in maxfilter.

Christopher Bailey wrote:

[Dear NEUROMEG list readers: Below is a correspondence I started earlier, and the reply by Dr. Nenonen from Neuromag. Had some troubles with my JISCmail account...]

Dear Jukka,

Thank you for your swift reply. Here are some follow-ups:

Q1) We see a clear difference between the QUAT channels written by -headpos and the CHPI channels written by -movecomp (screenshot attached). In a file acquired while I gently nodded the phantom continuously, the y- and ax-parameters behave as one would expect. When looking at the estimated head positions (in Maxfilter GUI), the _quat.fif file shows smooth motion parameters, whereas _tsss_mc.fif shows the rougher 10-second-step behaviour. I of course believe you (!!) when you say that the actual head position is indeed estimated at the same rate in both analyses, but the information we can read out of the files seems to be distinct, and I'd like to understand it a bit better.


Indeed, maxfilter updates the head position less frequently when tSSS is used. The cHPI signals are estimated in the same way in both cases, but the movement velocity is low enough
to judge that new head positions are needed less frequently than once per second. I will still use your data for more detailed debugging if this has effects on the output data.

In case the attachment doesn't make it through, here is a public link to the file:
http://dl.dropbox.com/u/14937634/motionpar-headpos-vs-movecomp_tSSS.pdf

I get that -movecomp actually "moves the head" (hence the name... ;), so it may make perfect sense that the CHPI channels reflect this. However, given that I've asked maxfilter to use the initial head position, shouldn't the CHPI then logically just be FLAT, fixed to the initial position...? This would not be very exciting data, but I really don't understand what the 10-sec-step data actually represents...
Q4 & Q5) OK, I see I've confused the head vs. device coordinate systems, the -origin is of course in the head frame by default. What I'm getting at is the use of -trans default when doing multi-subject analysis in sensor-space. That option seems to be a good way of normalizing some of the inter-subject variability in head placement in the helmet, and thus get a less blurred representation of the average responses (e.g. power) in sensor-space. What I'm concerned about is that there can be quite a bit of difference in (typically) the z-coordinate, depending on head shape and body (neck) form. So some subjects are further away from the "default" origin than others, and thus the head position normalization might induce extra noise (esp. in vertex sensors) in those subjects that were furthest from "default". Having now (properly) read through the manual, this is exactly what you refer to in 6.2.3.


Yes, there may be big variations in the head size and how 'deep' the subject heads are. Therefore, you should try to match the SSS origin to each subject as well as possible,
using MRI (when available) or fit to isotrak. In the latter case, the outcome however depends on how the digitizations were performed. For example, large number of points
digitized on the face or below ears is likely to distort the sphere fit.

MaxFilter uses the same procedure than xfit and mrilab, namely all digitization points are inluded in the sphere fit. I have made a small utility program which omits points
on the face and below the ears, and hopefully provides an origin which matches bettwer with the curvature of temporal, paritetal and occipital areas.
Let me know if you are interested to try it.

Q6) What is the "default" position, when using "-trans default"? Is it (0,0,0)_device, or (0, 13, -6)_device, or something else? I'm sorry if this is stated somewhere, but I couldn't find it...


It is (0,0,0) in device frame; the program moves the selected SSS origin there.

Best,

Chris

Best regards, Jukka

--

================================
Dr. Jukka Nenonen
Manager, Method development
Elekta Oy
Street address: Siltasaarenkatu 18-20A, Helsinki, Finland
Mailing address: P.O. Box 34, FIN-00531 HELSINKI, Finland
Tel: +358 9 756 240 85 (office), +358 400 249 557 (mobile),
     +358 9 756 240 11 (fax), +358 9 756 2400 (operator)
E-mail: [log in to unmask]<mailto:[log in to unmask]>
http://www.elekta.com/healthcare_international_elekta_neuromag.php

Top of Message | Previous Page | Permalink

JiscMail Tools


RSS Feeds and Sharing


Advanced Options


Archives

April 2024
May 2023
January 2023
March 2022
January 2022
December 2021
November 2021
May 2021
September 2020
August 2020
July 2020
May 2020
April 2020
January 2020
December 2019
June 2019
February 2019
January 2019
December 2018
November 2018
October 2018
September 2018
August 2018
July 2018
May 2018
April 2018
March 2018
February 2018
January 2018
November 2017
October 2017
September 2017
August 2017
March 2017
December 2016
September 2016
July 2016
April 2016
January 2016
August 2015
July 2015
June 2015
March 2015
December 2014
August 2014
May 2014
April 2014
January 2014
December 2013
November 2013
October 2013
September 2013
June 2013
March 2013
February 2013
January 2013
December 2012
November 2012
October 2012
July 2012
May 2012
March 2012
February 2012
September 2011
July 2011
June 2011
May 2011
April 2011
March 2011
October 2010
September 2010
August 2010
July 2010
June 2010
May 2010
April 2010
February 2010
January 2010
December 2009
November 2009
October 2009
August 2009
July 2009
June 2009
May 2009
April 2009
March 2009
February 2009
January 2009
November 2008
October 2008
September 2008
August 2008
July 2008
June 2008
May 2008
March 2008
January 2008
December 2007
November 2007
October 2007
September 2007
August 2007
July 2007
June 2007
May 2007


JiscMail is a Jisc service.

View our service policies at https://www.jiscmail.ac.uk/policyandsecurity/ and Jisc's privacy policy at https://www.jisc.ac.uk/website/privacy-notice

For help and support help@jisc.ac.uk

Secured by F-Secure Anti-Virus CataList Email List Search Powered by the LISTSERV Email List Manager