Hi,
I too have just hit this buglet while installing an EMI cream server.
Do you think it should be placed in
the yaim document (https://twiki.cern.ch/twiki/bin/view/LCG/YaimGuide400)?
Steve
Alessandro Paolini wrote:
> Il 27/02/2012 11:58, Mario David ha scritto:
>> hola Arnau
>> I also came across it last Friday (storm in particular)
>>
>> I have just set
>>> BDII_DELETE_DELAY=0
>> in the site-info, of course the point is as you say, what is the
>> reasonable value for a resource level bdii??
>> probably, just by reading the name of the variable, 0 is OK, but it
>> has to be documented (I didn't check if it is or not)
>>
>> probably better to open a ggus ticket for it
>>
>> Mario
>>
>> On Feb 27, 2012, at 10:50 AM, Arnau Bria wrote:
>>
>>> Hi all,
>>>
>>> I'm upgraded our WMS and I've found that yaim complains about missing
>>> BDII_DELETE_DELAY.
>>>
>>>
>>> INFO: Executing function: config_glite_locallogger_check
>>> INFO: Executing function: config_bdii_5.2_check
>>> ERROR: BDII_DELETE_DELAY is not set
>>> ERROR: Error during the execution of function: config_bdii_5.2_check
>>> ERROR: Error during running check functions.
>>> ERROR: Please define your missing variables ! Exiting.
>>> ERROR: One of the functions returned with error without
>>> specifying its nature !
>>>
>>> Quick googling gives no explanation about this parameter, nor YAIM site
>>> (https://twiki.cern.ch/twiki/bin/view/LCG/YaimGuide400).
>>>
>>> Anyone could explain what's this new parameter for ? An an appropriate
>>> value for WMS / BDII / CE, etc...?
>>>
>>>
>>> TIA,
>>> Arnau
>>>
> Hi all,
> I'm installing a voms server and I've run into the same problem.
> I've seen that this new yaim variable is mentioned in the EMI web site
> http://www.eu-emi.eu/emi-1-kebnekaise-updates/-/asset_publisher/Ir6q/content/update-13-17-02-2012#Installation_and_configuration
>
>
> and in the BDII reference card there is an example on how to set it
> (0, as Mario suggested :-)
>
> https://tomtools.cern.ch/confluence/display/IS/BDII
>
> Cheers,
> Alessandro
>
--
Steve Jones [log in to unmask]
System Administrator office: 220
High Energy Physics Division tel (int): 42334
Oliver Lodge Laboratory tel (ext): +44 (0)151 794 2334
University of Liverpool http://www.liv.ac.uk/physics/hep/
|