Thank you, John,
It could be the multi-frame DICOM format, but it is strange that most of
the subjects (~80%) are converted correctly.
Best Regards
Roberto
On Lun, 12 de Diciembre de 2011, 2:22 pm, John Ashburner dijo:
> My best guess is that your scans use the relatively new multi-frame
> DICOM format. This is something that Phillips uses, but Siemens does
> not seem to have adopted. Because most of the DICOM files that I
> encounter are from Siemens scanners, I haven't got yet around to
> figuring out what to do with multi-frame.
>
> There are a number of packages that may be able to deal with the
> conversion of those data. I'd suggest taking a look at
> http://www.nitrc.org/search/?type_of_search=group&cat=536:Format+Conversion
> or http://idoimaging.com/ for possible solutions.
>
> Best regards,
> -John
>
> On 12 December 2011 09:44, Roberto Roiz <[log in to unmask]> wrote:
>> Dear SPMers,
>>
>> When running DICOM import from SPM 8 I receive the following error
>> message:
>>
>> "Cant find "Image Pixel" information for
>> ""/home/roberto/Desktop/Convert_Nifti_Phillips/405_001/0". ",
>>
>> for each dicom image. Surprisingly, I receive this error only in about
>> 20% of my subjects all taken with the same scanner (Phillips 3T) and
>> same parameters.
>>
>> I've found a similar question in the list but haven't seen any reply so
>> far.
>>
>> Any suggestion?
>>
>> Thank you.
>>
>> Roberto Roiz
>
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud service.
> For more information please visit http://www.symanteccloud.com
> ______________________________________________________________________
>
|