Dear Charline,
I don't know for sure but one possibility is that your channel types
are not set correctly any more and all the channels appear in the
'Other' tab. In general I would suggest you instead of converting your
clean data back to SPM to get from FT the montage matrix representing
ICA component removal and apply it to your SPM dataset using
spm_eeg_montage.
Best,
Vladimir
On Wed, Oct 12, 2011 at 2:20 PM, Urbain Charline <[log in to unmask]> wrote:
> Dear Vladimir,Dear SPMers,
>
> I have a problem concerning the convertion of FieldTrip data into
> GUI-readable SPM data.
>
> Specifically, the problem is the following: I successfully converted SPM
> data (preprocessed with SPM *.beffspm.mat)
>
>
>
> into Fieldtrip data to perform an ICA analysis. After removing the
> artifactual ICs from the data,
> I converted the resulting Fieldtrip data structure into SPM structures .dat
> and .mat using the function
> spm_eeg_ft2spm, which seems to work.
>
>
>
>
> However, I am now unable to display the data into the GUI. Do you know why?
>
> Thank you very much for help!
>
> Charline
>
>
>
>
>
|