Hello,
Tim says:
"The mapping is worked out to preserve the 'onebond' dimensions, so if in
ARIA there are H1-X1 H2-(X2) dimensions (with X2 not used in 3Ds) the
bound CCPN dims naturally go in the H1-X1 slot and the other proton in H2,
so it uses the reference mapping, but is not sensitive to CCPN order."
Wayne
On Tue, 2 Aug 2011, Robert Dagil wrote:
> Hi CCPN
>
> I have a question/concern about doing an Aria2 calculation together with CCPN project. It all boils down to the different dimensions in the different spectra in the Aria2 project. Does CCPN/Aria2 transfer the dimensions as they are stated in the reference dimension mapping in the Analysis project? I'm concerned since I have different mappings in all my NOESY spectra, and get a lot of violated peaks after my structure calculations.
>
>
> Kind regards
>
> Robert Dagil, University of Copenhagen, Denmark
>
|