Dear Pegah,
If you want to do source reconstruction or DCM, coregistration is done
as part of 'M/EEG head model specification' batch. Unfortunately,
there is no batch module at the moment for loading custom sensor
locations. So you can either do it via the GUI for each subject or
write a short script. You can get an example of such a script if you
take a file where you loaded the sensors via GUI and then create a
script from the file's history (see section 12.10.2 in the manual).
Best,
Vladimir
On Thu, Jun 9, 2011 at 12:33 PM, Tayaranian Hosseini P.
<[log in to unmask]> wrote:
> Dear SPMers,
>
> I am trying to preprocess my EEG data in Batch system (I have many subjects that is why I am using Batch). I can find all preprocessing functions except for Sensor locations and Coregister in the Batch tool. My data includes the fiducial and sensor locations in it so in GUI, when "prepare"ing the data, I will "assign default" for sensors and after that click on "coregister" and my data is ready to be used for further analysis. It will not ask for any fiducial. But in Batch system, the only "Coregister" function I found, needed some parameters that I had not any information about and I could not find sensor allocation at all. Can someone help me out here.
>
> Thanks,
> Pegah
>
> --------------------------------------------------------
> Pegah Tayaranian Hosseini
> PhD Student
> Room 4077, Tizard building (13)
> Institute of Sound and Vibration Research
> University of Southampton, SO17 1BJ, UK
>
> Tel: 023 8059 2850
> email: [log in to unmask]
|