Is there NCS? (How's the self rotation look? How about the native
patterson?)
Does your search model have flexible loops? You may have the right
solution, but the flexible loops may be in a different conformation
and cause clashes. Trim the search model to the conserved / structured
domains.
Do you have *any* anomalous signal? (whether you collected Sulfur-SAD,
you have a metalloprotein, etc). These can be useful in verifying the
correctness of the MR solution.
> I use only one chain of the monomer model
Why?
F
On Mar 15, 2011, at 12:41 AM, Careina Edgooms wrote:
> Dear CCP4 members
>
> I have a confusion with molecular replacement. I wish to solve a
> monomeric protein in P21 where there are 2 monomers in asymmetric
> unit. I have a search model that also has 2 monomers in asymmetric
> unit.
>
> First I try using Phaser. I use only one chain of the monomer model
> and search for 2 copies. This gives a good solution that refines
> with low R-factor but it shows many clashes. In other words, the 2
> monomers are too close together and there are clashes where they
> meet. Then I try using Phaser and both chains of the model and
> search for 1 copy. This does not give a solution and says asymmetric
> unit is too full. Then I try using MolRep with the 2 chain search
> model. It gives solution that looks better because you can see that
> the 2 monomers do not physically clash but it refines very badly
> giving R factors of about 50%
>
> So I am confused. What am I doing wrong? Please help me with
> suggestions
> Many thanks
> Careina
>
>
---------------------------------------------
Francis E. Reyes M.Sc.
215 UCB
University of Colorado at Boulder
gpg --keyserver pgp.mit.edu --recv-keys 67BA8D5D
8AE2 F2F4 90F7 9640 28BC 686F 78FD 6669 67BA 8D5D
|