Hi Steve
Thanks so much for the guidance. For some reason my install of Genie did not have the standard data directory and files. I have added those and the error is gone and things from the test commands appear to complete correctly.
Please close this issue.
Best wishes!
Darren
On Dec 27, 2010, at 2:20 PM, Steven Dytman wrote:
> Darren,
> I have working version of version 2.6.0 here, your command runs fine.
> Error statement seems to say there is a missing data file. Unlikely,
> but check for files intranuke_xsections-XX.dat in $GENIE/data/hadron_xsec.
> You should have 4 files XX = NN, NA, piA, and piN.
>
> You say this shows up at end of long printout. Please send that printout.
> At the moment, not clear what your problem is. Have you run other GENIE
> applications?
>
> Do you have access to working version, e.g. at TRIUMF or Regina? You can compare
> your setup with theirs.
>
> regards,
> Steve Dytman
>
> Darren Grant wrote:
>> Hi
>>
>> Please note I am a very new user of GENIE, but have been unable to find a solution to this on the archive searches.
>> I have completed the compile of production release 2.6.0 without any errors on the system here. In execution of the test command from the manual
>>
>> ./bin/ghAevgen -n 10000 -p 211 -t 1000080160 -k 0.2
>>
>> I am seeing the following error at the end of all the output
>>
>> ghAevgen: INukeHadroData.cxx:173: void genie::INukeHadroData::LoadCrossSections(): Assertion `! gSystem->AccessPathName(datafile_NN. c_str())' failed.
>> Aborted
>>
>> I am unsure how to proceed with this error. I note that I have compiled with pyhia6 and root 5.24b on a x86_64 box running Linux 2.6.18-194.11.4.el5 with gcc (GCC) 4.1.2 20080704 (Red Hat 4.1.2-48) and GNU Fortran (GCC) 4.1.2 20080704 (Red Hat 4.1.2-48).
>>
>> Please let me know what information etc you might require to help debug.
>>
>> Best wishes
>> Darren
>>
>
|