That should work - providing the fMRI are not too distorted and the file
formats are correct (with appropriate values in the headers). There are
also some tricks that can improve the registration accuracy
(skull-stripping and bias correction of anatomical scans).
Best regards,
-John
On Sun, 2010-01-31 at 04:28 -0800, kambiz rakhshan wrote:
> Dear all,
>
> I have a question regarding coregistration between functional and
> structural images.The main intention is using DARTEL for fMRI
> normalization to MNI coordinate. In order to go for it, the Individual
> mean fMRI time series volume should be coregistered to Individual T1
> volume, and then the coregistration parameter should be applied to the
> whole fMRI time series .In order to do this, I did the following step:
>
> coreg:estimate
>
> ref.img: T1 structural image
> sou.img: Mean fMRI
> other images: all the realigned fMRI volumes
>
> Is that a corect way of applying coregistration parameter to the whole
> fMRI time series data?
>
> Many thanks
>
>
>
>
>
--
John Ashburner <[log in to unmask]>
|