Hi,
I guess what I had in mind was extracting two or more slices and then
having them displayed in another window either separately or overlaid.
If these could be scaled separately as well that would be great ( I
can't seem to scale different cross-hair traces independently at the
moment - is that intentional or a bug?) An intensity scale for the
slices would be good too if separate scaling were possible.
Cheers,
Jo
Wayne Boucher wrote:
> Hello,
>
> Do you just want to look at them? Because you can do that with traces
> (right mouse click Window --> Crosshair traces or Add side traces).
> But if you want to quantify things then it would be useful to know
> what you want. So we are in the process of setting up a group (mostly
> of pharma people) to look at what 1D functionality there should be
> (well, and other things, but that would be a big part). We're hoping
> to have an informal meeting in November but if you have any
> suggestions we'd be glad to hear them.
>
> Wayne
>
> On Thu, 8 Oct 2009, Jo Claridge wrote:
>
>> Hi,
>>
>> I would like to compare two 1D slices of a 2D spectrum and I found this
>> thread from a few years ago, is there any way to overlay two (or more
>> come
>> to that) slices in analysis 2?
>>
>> cheers,
>> Jo Claridge
>>
>>
>> On Tue, 15 Aug 2006 11:28:14 +0100, Gary S. Thompson
>> <[log in to unmask]>
>> wrote:
>>
>>> Wayne Boucher wrote:
>>>
>>>> Hello,
>>>>
>>>> If we (Tim and I) understand what you mean by comparing 1D slices then
>>>> that is not possible currently.
>>>>
>>> yep that was my guess, but I thought I would check I hadn't missed
>>> anything
>>>
>>>> (So you want to click at x1, y1 and x2,
>>>> y2 and have the two slices drawn on top of each other??) And I
>>>> guess we
>>>> could add a slice menu...
>>>>
>>>>
>>>
>>> basically I want to compare lineshapes alonglines in the xy plane for
>>> two spin systems with different x and z coordinates
>>>
>>> i.e. if I have an hnca connection between residue 3 and 4 I want to
>>> compare the 13C lineshape of the interpeak on 4 with the intrapeak
>>> of 3....
>>>
>>> regards
>>> gary
>>>
>>>> Wayne
>>>>
>>>> On Fri, 11 Aug 2006, gary thompson wrote:
>>>>
>>>>
>>>>
>>>>> Dear All
>>>>> I have been using the 1d slice feature a bit over that last few
>>>>> days and
>>>>> there is one feature I needs which I can seem to achieve. Is there
>>>>> a way I
>>>>> can compare 1d slices? for example if i have a hnca and want to
>>>>> compare the
>>>>> 1d slices from two strips from peaks with different 1H-15N
>>>>> positions this
>>>>> seems to be impossible...
>>>>>
>>>>> regards
>>>>> gary
>>>>>
>>>>> n.b. it would be really nice if there was a drop down on windows
>>>>> like strips
>>>>> spectra contours etc called slices which allowed easy access to
>>>>> the slice
>>>>> functions ..
>>>>>
>>>>>
>>>>>
>>>>
>>>> .
>>>>
>>>>
>>>>
>>>
>>>
>>> --
>>> -------------------------------------------------------------------
>>> Dr Gary Thompson
>>> Astbury Centre for Structural Molecular Biology,
>>> University of Leeds, Astbury Building,
>>> Leeds, LS2 9JT, West-Yorkshire, UK Tel. +44-113-3433024
>>> email: [log in to unmask] Fax +44-113-2331407
>>> -------------------------------------------------------------------
>>
>
--
Jolyon K. Claridge
PhD Student
Biomolecular NMR
Institute of Fundamental Sciences
Massey University
Turitea Campus
Palmerston North
New Zealand 4442
email: [log in to unmask]
phone: +64 6 356 9099 ext: 3569
------------------------------------------------------------------------
|