Hi,
a window with horizontal strips shows the wrong (vertical) arrow icons after
being turned off and on again.
Good news is, a disabled windows destroys all the widgets it created but
switching a window off and on again is now a way to reproduce this:
Exception in Tkinter callback
Traceback (most recent call last):
File "/opt/ccpnmr_v2/rtl/lib/python2.6/lib-tk/Tkinter.py", line 1410, in
__call__
return self.func(*args)
File "/opt/ccpnmr_v2/ccpnmr2.1/python/ccpnmr/analysis/popups/WindowPopup.py",
line 714, in getWindowLocation
self.window.location = (x, y)
File "/opt/ccpnmr_v2/ccpnmr2.1/python/ccpnmr/api/Analysis.py", line 31951,
in setLocation
notify(self)
File "/opt/ccpnmr_v2/ccpnmr2.1/python/ccpnmr/analysis/popups/WindowPopup.py",
line 689, in setWindowLocation
self.geometry(location)
File "/opt/ccpnmr_v2/ccpnmr2.1/python/memops/gui/BasePopup.py", line 305, in
geometry
Tkinter.Toplevel.geometry(self, location)
File "/opt/ccpnmr_v2/rtl/lib/python2.6/lib-tk/Tkinter.py", line 1492, in
wm_geometry
return self.tk.call('wm', 'geometry', self._w, newGeometry)
TclError: bad window path name ".82946600.101908704"
bye
Tolga
Am Mittwoch, 7. Oktober 2009 schrieb Tolga Helmbrecht:
> I forgot to mention, it's random, after some time of usage. In general it
> works fine with the big windows, turning them on and off for some time. So
> will not be easy to reproduce. I saw the traceback once before but had no
> clue where it came from. it was possible to resize the windows to span the
> screens afterward again. So no obvious malfunction directly after this
> sudden resize event.
>
> Tolga
>
> Am Mittwoch, 7. Oktober 2009 schrieb Wayne Boucher:
> > Hello,
> >
> > I haven't a clue what this one is about, although the bad path messages
> > mean that there is a widget that Analysis is trying to deal with (quite
> > probably a canvas for the contours) that no longer exists as far as the
> > Tcl/Tk world is concerned. I'll see if I can find a dual screen tomorrow
> > and reproduce.
> >
> > Wayne
> >
> > On Wed, 7 Oct 2009, Tolga Helmbrecht wrote:
> > > Hello,
> > >
> > > clicking the Peaks button in a sprectum window just caused strange
> > > behaviour. The window position and size got reset. I'm working with a
> > > dual screen TwinView setup and two windows spanned more than one
> > > monitor screen before. They were positioned and resized to fit one.
> > > This printed the first traceback.
> > > Afterwards everything looked fine but the the two windows caused the
> > > other two errors every time while moving them around. There where two
> > > other windows active, they did not print a traceback while moving.
> > > After restarting analysis the tracebacks are gone.
> > > This is tcl/tk 8.5.7.
> > >
> > > Bye
> > > Tolga
--
Tolga Helmbrecht
Leibniz-Institut für Molekulare Pharmakologie (FMP)
Abt. NMR-unterstützte Strukturforschung
AG Solution NMR
Robert-Roessle-Str. 10
13125 Berlin
Germany
Tel. +49-30-94793-279
Fax +49-30-94793-230
Web http://www.fmp-berlin.de/solutionnmr.html
E-Mail [log in to unmask]
|