Hi Guillaume,
I forgot to mention that we already have the latest updates (3381 I
believe). Are there specific files we can look at to help troubleshoot
this problem?
Thanks,
Xin
On Wed, Oct 7, 2009 at 5:56 AM, Guillaume Flandin
<[log in to unmask]> wrote:
> Dear Xin,
>
> what you describe seems to be symptomatic of a bug that was present in
> updates 1111 of SPM5 so I would suggest that you install the most recent
> updates from:
> ftp://ftp.fil.ion.ucl.ac.uk/spm/spm5_updates/
> so that newer files overwrite existing files.
> Note that if it is indeed the cause of the problem you describe, you
> will have to specify and estimate your models again as the SPM.mat has
> been somehow corrupted.
>
> Best regards,
> Guillaume.
>
>
> Xin Zheng wrote:
>> Dear SPM users.
>>
>> We have encountered a persistent problem with SPM5 contrast manager.
>> We first ran the model and set up the contrast for analysis 1. We then
>> opened another analysis (analysis 2) that was set up by another
>> computer in the network. When we opened the contrast manager for
>> analysis 1 again, only the contrasts pertaining to analysis 2 (not 1)
>> popped up in the GUI. However, when we checked the directory where
>> analysis 1 was stored, it seemed to contain all the constrasts we
>> originally set up.
>>
>> We also noticed that in the SPM.mat file in analysis 1, the 'swd'
>> variable pointed to the directory for analysis 2. Is this a path issue
>> in SPM?
>>
>> We have tried restarting SPM - but it's still not showing the data for
>> analysis 1. All the analyses were done in their own directories.
>>
>> Has anyone else encountered this problem? Any help would be much appreciated.
>>
>> Thanks,
>> Xin & Catherine
>
> --
> Guillaume Flandin, PhD
> Wellcome Trust Centre for Neuroimaging
> University College London
> 12 Queen Square
> London WC1N 3BG
>
>
|