Try MRIcron instead, because it is NIfTI compatible and should therefore
deal properly with the NIfTI format images that SPM5 generates.
http://www.sph.sc.edu/comd/rorden/mricron/
Best regards,
-John
On Wed, 2009-07-08 at 16:23 +0200, Andreas Hahn wrote:
> Dear SPM experts,
>
> I have a problem regarding the left-right-orientation in SPM5 [sorry,
> I'm sure this problem has been adressed more than once but I didn't find
> it in the archive]:
>
> In my SPM results a cluster is reported with the x-coordinate = 12mm,
> however, in my spmT-file (either viewed with MRIcro or PMOD) this
> cluster is exactly on the other side (x-coordinate = -12mm).
> My spm defaults are set to defaults.analyze.flip=1, however, it seems
> that not the resulting analyze-file is flipped (I'm 100% sure about this
> because I have a subject with a unilateral tumor...) but the results in
> SPM5 are (coordinates in graphics window) - is this correct?
>
> Thanks in advance,
> Andreas.
--
John Ashburner <[log in to unmask]>
|