Thank you Steve!
Nader Metwalli
Bioengineering Ph.D. Candidate
The Wallace H. Coulter Department of Biomedical Engineering,
Georgia Institute of Technology / Emory University,
Atlanta, GA, U.S.A.
Tel: (404) 712 4439
----- Original Message -----
From: "Steve Smith" <[log in to unmask]>
To: [log in to unmask]
Sent: Wednesday, June 3, 2009 2:25:29 AM GMT -05:00 US/Canada Eastern
Subject: Re: [FSL] Meaning of the range of values output via tbss_fill
Hi - they are not - except that they are all derived from values
"over" the threshold that you selected. First the p-value image is
thresholded, then binarised, then dilated, etc - see the script for
detailed comments.
Cheers.
On 2 Jun 2009, at 17:28, Nader Metwalli wrote:
> Hello FSL experts,
>
> In using tbss_fill on the tbss_tfce_corrp_tstats files and
> thresholding at significance level 0.05 (i.e. using threshold 0.95)
> how are the new values in the tbss_fill file related to the actual
> FWE corrected p-values?
>
> Thanks,
> Nader
>
---------------------------------------------------------------------------
Stephen M. Smith, Professor of Biomedical Engineering
Associate Director, Oxford University FMRIB Centre
FMRIB, JR Hospital, Headington, Oxford OX3 9DU, UK
+44 (0) 1865 222726 (fax 222717)
[log in to unmask] http://www.fmrib.ox.ac.uk/~steve
---------------------------------------------------------------------------
|