It is possible and should definitely be tried.
SHARP works very well for MIRAS phasing in our experience.
-Bjørn
Arnon Lavie wrote:
> Hi,
>
> we collected SAD data sets to 3.0 A on our protein, once as a Se-Met
> protein and once soaked with a mercury compound. Data statistics
> indicate an anomalous signal in both data sets. However, the maps are
> not great. Is it possible to combine the phase information from the two
> data sets? We have been using Solve/Resolve for the individual SAD data
> sets. If any of you know of a solve script (or an alternative program)
> that would combine the two, please reply.
>
> Arnon
>
--
Bjørn Panyella Pedersen, PhD
Postdoc
PUMPKIN, Centre for Membrane Pumps in Cells and Disease
University of Aarhus, Dept. Molecular Biology
Gustav Wieds Vej 10C DK-8000 Aarhus C, Denmark
Phone: +45 89425261
E-mail: [log in to unmask]
http://www.bioxray.au.dk
|