A long time ago, I wrote a little program for turning spot picks into a
PDB file that you could load up and rotate around in a graphics program
(such as O, at the time):
http://bl831.als.lbl.gov/~jamesh/pickup/spt2xyz.com
this one works on the *.spt files that comes out of MOSFLM. You can
concatenate *.spt files for each of your images to get the full data set
represented.
I also wrote one that works on ADSC images if you have the DPS program
installed:
http://bl831.als.lbl.gov/~jamesh/pickup/adsc2pdb.com
but it only works for the "common" coordinate system convention we use
at ALS and SSRL. Not sure about other beamlines.
The algorithm for converting spot positions into reciprocal space is
not exactly new, as it is at the core of any and every autoindexing
program. All you do is figure out the take-off angle of the diffracted
ray from the crystal and then calculate the coordinate where this line
intersects the Ewald sphere. Specifically, the "distortion" is:
distortion = lambda*sqrt((Xdet)^2+(Ydet)^2+(dist)^2)
where:
lambda - the x-ray wavelength in A
Xdet - X coordinate of the spot relative to the beam center (in mm)
Ydet - Y coordinate of the spot relative to the beam center (in mm)
dist - the crystal-to-film distance (from crystal to direct-beam
spot, in mm)
You then use this "distortion" to compute the x-y-z coordinate of the
reciprocal-lattice point in reciprocal space:
x' = Xdet/distortion
y' = Ydet/distortion
z' = dist/distortion - 1/lambda
Yes, there are x-y-z coordinates in reciprocal space. They all have
units of inverse Angstroms. Of course, these x',y',z' coordinates are
at the phi value of the image you picked spots on. To get the
coordinates at phi=0, you need to "un-roate" them:
x = x'*cos(phi)-z'*sin(phi)
y = y'
z = x'*sin(phi)+z'*cos(phi)
where some people can probably tell that in this convention the phi axis
is right-handed and parallel to the "Ydet" axis of the detector.
The last step is to multiply these x,y,z coordinates by some reasonable
scale factor and put them into a PDB file. Maybe put the intensity in
the B-factor column, so that you can color it. Then you need to find a
display program that can handle a million-atom PDB. Does anyone have
one of those?
Ideally, what one would like to do is make an electron density map with
pixel-to-pixel correspondence to the image. All you do is apply the
above formulas to each pixel, do a Lorentz-Polarization correction, and
then just render the data set as a map.
Sounds like there are a couple of commercial programs that do this in 2
dimensions. Problem with doing it in 3D is there are no programs that
can display an electron density map this big. In fact, I can't even get
CCP4 to write out map or mtz files bigger than 2 GB. I get "filesize
limit exceeded" errors (even though the filesystem can handle large
files). Is this a limitation of the 32-bit binaries? Can anyone help
me confirm that re-compiling CCP4 as 64-bit will fix this? This error
can be reproduced by trying to make a 2 A data set for the largest unit
cell in the PDB:
unique hklout test.mtz << EOF
RESO 2
SYMM 1
CELL 687.900 687.900 1933.300 90 90 90
DEFAULT 1
LABOUT F=F
END
EOF
Thanks!
-James Holton
MAD Scientist
Ian Tickle wrote:
> But I thought what you wanted was to reconstruct the diffraction pattern
> (i.e. streaks, TDS, ice rings, zingers, warts & all) as a
> pseudo-precession image, not just display a representation of the
> integrated intensities. That surely would be much more useful, then one
> could see whether the apparent systematic absence violations were just
> streaks from adjacent spots, TDS, ice spots etc that have fooled the
> integration algorithm. That would be much more useful! In the days
> when we had real precession cameras this was how you assigned the space
> group.
>
> Cheers
>
> -- Ian
>
>
>> -----Original Message-----
>> From: [log in to unmask] [mailto:[log in to unmask]]
>>
> On
>
>> Behalf Of Francis E Reyes
>> Sent: 25 June 2009 17:32
>> To: [log in to unmask]
>> Subject: Re: [ccp4bb] From oscillation photographs to seeing specific
>> sections of reciprocal lattice.
>>
>> Thanks all who replied.
>>
>> Looks like HKLView is it..
>>
>>
>>
>> Oddly I couldnt find it anywhere in the ccp4i interface (shouldn't it
>> at least appear under Program List)?
>>
>> FR
>>
>> On Jun 25, 2009, at 10:24 AM, Francis E Reyes wrote:
>>
>>
>>> Hi all
>>>
>>> Is there software that will take oscillation photographs and
>>> construct a precession-like photo of specific layers of the
>>> reciprocal lattice (say h0l), for inspection of the systematic
>>> absences, etc?
>>>
>>> Thanks
>>>
>>> FR
>>>
>>> ---------------------------------------------
>>> Francis Reyes M.Sc.
>>> 215 UCB
>>> University of Colorado at Boulder
>>>
>>> gpg --keyserver pgp.mit.edu --recv-keys 67BA8D5D
>>>
>>> 8AE2 F2F4 90F7 9640 28BC 686F 78FD 6669 67BA 8D5D
>>>
>> ---------------------------------------------
>> Francis Reyes M.Sc.
>> 215 UCB
>> University of Colorado at Boulder
>>
>> gpg --keyserver pgp.mit.edu --recv-keys 67BA8D5D
>>
>> 8AE2 F2F4 90F7 9640 28BC 686F 78FD 6669 67BA 8D5D
>>
>
>
>
> Disclaimer
> This communication is confidential and may contain privileged information intended solely for the named addressee(s). It may not be used or disclosed except for the purpose for which it has been sent. If you are not the intended recipient you must not review, use, disclose, copy, distribute or take any action in reliance upon it. If you have received this communication in error, please notify Astex Therapeutics Ltd by emailing [log in to unmask] and destroy all copies of the message and any attached documents.
> Astex Therapeutics Ltd monitors, controls and protects all its messaging traffic in compliance with its corporate email policy. The Company accepts no liability or responsibility for any onward transmission or use of emails and attachments having left the Astex Therapeutics domain. Unless expressly stated, opinions in this message are those of the individual sender and not of Astex Therapeutics Ltd. The recipient should check this email and any attachments for the presence of computer viruses. Astex Therapeutics Ltd accepts no liability for damage caused by any virus transmitted by this email. E-mail is susceptible to data corruption, interception, unauthorized amendment, and tampering, Astex Therapeutics Ltd only send and receive e-mails on the basis that the Company is not liable for any such alteration or any consequences thereof.