Dear Dr. Vladimir and SPM experts,
thanks your help. could you tell me if I use convert button to import .cnt
data, which spm script I should change the autodetect to ns_cnt32 ?
I also have another question. I use EEGlab and make epoch from continous
EEG and save it as .set data. when I use spm8 to convert this data, it can
import it but the display of epoch EEG is wrong. all channels data crowd in
together. is there any thing wrong ?
thanks your help
kl chen
On Sat, 25 Apr 2009 15:04:03 +0100, Vladimir Litvak
<[log in to unmask]> wrote:
>This is a known problem. At the moment there is no way for SPM to
>automatically distinguish between 32 and 16 bit Neuroscan files. You
>can provide this information if you use the batch version of
>conversion. Press the 'Batch' button. Go to SPM->M/EEG->M/EEG
>Conversion and in 'Input data format' change autodetect to ns_cnt32 .
>The rest of the parameters are similar to GUI conversion.
>
>Best,
>
>Vladimir
>
>On Sat, Apr 25, 2009 at 2:16 PM, Kl chen <[log in to unmask]> wrote:
>> Dear SPM experts,
>> I use Neuroscan 32 bits data to convert it into spm8 data format. It can go
>> through the whole process smoothly but the final results seem spm8 read it
>> as it is 16 bits format. The whole EEG duration is 2 times longer than it
>> really is. Could someone help to instruct me which default value should
>> change so that I can read it correctly under spm8 ?
>> thanks in advance.
>> kl chen
>>
|