Bonjour Jean-Michel,
> I noticed recently that the job's working directory is not always a
> new directory named after the job id. I am not sure if it is related
Do you have examples?
> but I observed also that the EDG_WL_JOBID variable is not always filled
> as it appears in the LCG-CE globus-gatekeeper's log :
>
> cat /var/log/globus-gatekeeper.log | grep EDG_WL_JOBID
> [...]
> JMA 2009/04/20 09:27:14 GATEKEEPER_JM_ID
> 2009-04-20.09:27:14.0000004358.0000000000 has EDG_WL_JOBID
> 'https://grid02.lal.in2p3.fr:9000/l1ALuA_Iib_oxJQI1lTJZA'
> JMA 2009/04/20 09:27:17 GATEKEEPER_JM_ID
> 2009-04-20.09:27:17.0000004374.0000000000 has EDG_WL_JOBID ''
> JMA 2009/04/20 09:28:20 GATEKEEPER_JM_ID
> 2009-04-20.09:28:20.0000005403.0000000000 has EDG_WL_JOBID
> 'https://grid02.lal.in2p3.fr:9000/QN84p_1sPkljClCST-sDDg'
> JMA 2009/04/20 09:28:21 GATEKEEPER_JM_ID
> 2009-04-20.09:28:21.0000005415.0000000000 has EDG_WL_JOBID ''
> [...]
That is normal. The EDG_WL_JOBID is only set for jobs sent by RB or WMS
nodes and directed to the batch system. The RB/WMS also sends "grid_monitor"
jobs running on the lcg-CE itself, and requests to clean up jobs that have
finished.
|