Hi,
I had generated the noe restraint list (2D H-H NOESY) by using Pipp and then
imported the list by format converter. If I wanted to generate synthetic
peak list for the same spectrum, then Analysis used to complain 'Peaks could
not be made due to missing resonances'. Once you make these missing
resonances by using 'Setup Resonances', it still doesn't generate a valid
peak list and this time it does not even give an error message. It generates
a peak list which is empty.
I see the same pattern for the constraints generated by CCPN, I export the
constraints in CNS format, then run some calculations, remove some
violations and then when I import the final constraint list, I get the same
response.
All these restraints are for the same 2D H-H NOESY spectrum with same
chemical shifts, I just did it two times (once in Pipp and then in CCPN).
Thanks,
Regards,
Lalit Deshmukh
UCONN, Storrs, CT 06269, USA
|