hari jayaram wrote:
> Hi paul,
> Kevin did write to me asking if I could submit a detailed bug report.
>
> Strangely, I could not reproduce the problem. I am still running
> revision 1950 ..On that day myself and one other person ( I think it was
> Dr Eleanor Dodson) reported that the rigid body fit zone ..was stopping
> after the first click.
>
> I have since used rigid body fit zone many times without any problem in
> rev 1950
>
> I had two more unrelated issues.
> # Add terminal residue and simultaneous movement
> Didnt coot previously also allow you to simultaneously rotate-translate
> a terminal atom concurrently with the addition.
I don't think so.
> Now in revision 1947 onwards. Clicking add terminal residue only allows
> you to move the atom around using the mouse . So all end residue
> additions are two steps , first add, then accept and then again rotate
> translate zone to position. Is this intended.
That is a bit tedious. Try these settings:
(set-add-terminal-residue-immediate-addition 1)
(set-add-terminal-residue-do-post-refine 1)
Also,
http://strucbio.biologie.uni-konstanz.de/ccp4wiki/index.php/Pauls-key-bindings-for-coot
Then "|" (bar) add a terminal residue to residue at the centre of the
screen (it will add it as stars initially (bug yet to be fixed)), but a
"t" will fix that.
> # Copy_from_ncs_master_to_others : creates all atoms as stars in ncs mates
I don't see that :-(.
Paul.
|