Dear Kristof,
This is a bug we are aware of. It will go as of the next release but for
the moment the easiest is if we send you a fixed executable. What is
your computer platform (please type 'uname' and let me know the output) ?
With best regards,
Victor
Kristof Van Hecke wrote:
> Dear all,
>
> When refining a DNA-structure (poor data, resolution 2.5) and using
> ARP/wARP Solvent 7.0.1. for water divining with CCP4 6.1.1 and GUI
> 2.0.4, I get the following error:
>
> QUITTING ... ARP/wARP module stopped with an error message:
> ARP_WARP_MODE_WILSON
>
>
> When checking the "warp_wilson_log" file, I get:
>
>
> Comments: Overall fit of the data to the Wilson curve:
>
> Comments: Problems Resolution range 5.15 to 4.89
> Comments: Problems Resolution range 4.89 to 4.67
> Comments: Problems Resolution range 2.89 to 2.84
> Comments: Possible reasons - missing overloads
>
> Solvent content 1.00
>
>
> Computed solvent content is too high - check your input
>
> ***** ERROR *****
>
> I was kind of surprised, because with the same data! and an older
> version of ARP/wARP, which was integrated in the Refmac5 program, I did
> not get any errors of this kind..!?
>
> Is there a way to circumvent this please..?
>
>
> Many thanks
>
> Kristof Van Hecke
>
>
>
>
> Disclaimer: http://www.kuleuven.be/cwis/email_disclaimer.htm
>
>
|