Hmm, this definitely sounds like it could be improved. Is this for
NmrPipe or for Bruker pseudo-3D data (well, it might be a problem for
both!)? (Just so I can see if I have some data I can try this out on.)
(So for Azara pseduo-3D data it should do it all automatically.)
Wayne
On Mon, 9 Feb 2009, Mark Pfuhl wrote:
> When I load a pseudo 3D spectrum a window pops up asking me for the point
> values, fair enough. But why does this window not have the correct number of
> entries, i.e. why do I have provide the correct number of fields? When I
> click on OK before the correct number is present I get an error message
> where it tells me how many points there are. Would it be possible to simple
> read out that value right at the start and generate an input template with
> the correct number of fields?
> If that is not possible : would it be possible to move the '+' and '-'
> buttons above the list? At the moment not only do I have to keep clicking a
> lot but I also have to move the mouse after each click because the list gets
> longer and moves the buttons.
> thanks,
> mark
>
|