Yes I agree with that!
-- Ian
> -----Original Message-----
> From: Andreas Förster [mailto:[log in to unmask]]
> Sent: 29 January 2009 16:26
> To: [log in to unmask]; Ian Tickle
> Cc: [log in to unmask]
> Subject: Re: [ccp4bb] Small lines in diffraction pattern (more info)
>
> Ian and Herman,
>
> does one want to convolute the electron density at all? I
> was under the
> impression that current thinking favors convolution of the model
> instead, i.e. placing both the helices in both orientations
> at partial
> occupancy and letting the refinement program figure things out?
>
>
> Andreas
>
>
> [log in to unmask] wrote:
> > Dear Ian and Margriet,
> >
> > You are right, the correction needs to be done on F, not on
> |F|^2. If I recall correctly (I did not do it myself), the
> assumption was that Fobs = 0.5*Fobs(A) + 0.5*Fobs(B), so
> Fcorrected(A) = 2*Fobs - Fcalc(B) where A and B are the two
> orientations. Since one does not have an observed phase, one
> would have to take calculated phases. I am unsure though, if
> that was done in practise and one did not just subtract the
> absolute values. Since the inhibitor is usually only a small
> part of the total scattering mass, the phases might not
> differ too much and therefore the error would not be too big.
> In case of superposition of base pairs, I guess that the
> differences in scattering between the different base-pairs is
> not too much, so one might also be able to get away with not
> using phases, but here you are the expert.
> >
> > Using this method, one could much better interpret the
> convoluted electron density, but one has to be very careful
> not introducing severe model bias. I would look in the
> literature in detail, what people from the HIV protease field
> had done to solve this problem.
> >
> > Cheers,
> > Herman
> >
>
> --
> Andreas Förster, Research Associate
> Paul Freemont & Xiaodong Zhang Labs
> Department of Biochemistry, Imperial College London
>
>
Disclaimer
This communication is confidential and may contain privileged information intended solely for the named addressee(s). It may not be used or disclosed except for the purpose for which it has been sent. If you are not the intended recipient you must not review, use, disclose, copy, distribute or take any action in reliance upon it. If you have received this communication in error, please notify Astex Therapeutics Ltd by emailing [log in to unmask] and destroy all copies of the message and any attached documents.
Astex Therapeutics Ltd monitors, controls and protects all its messaging traffic in compliance with its corporate email policy. The Company accepts no liability or responsibility for any onward transmission or use of emails and attachments having left the Astex Therapeutics domain. Unless expressly stated, opinions in this message are those of the individual sender and not of Astex Therapeutics Ltd. The recipient should check this email and any attachments for the presence of computer viruses. Astex Therapeutics Ltd accepts no liability for damage caused by any virus transmitted by this email. E-mail is susceptible to data corruption, interception, unauthorized amendment, and tampering, Astex Therapeutics Ltd only send and receive e-mails on the basis that the Company is not liable for any such alteration or any consequences thereof.
Astex Therapeutics Ltd., Registered in England at 436 Cambridge Science Park, Cambridge CB4 0QA under number 3751674
|