Also note that it would not be good practice to remove artefact ICA
components in EEGLAB and then import the data back to SPM and try to
source reconstruct it. There is a proper way to do it which would be
quite easy to implement if there is interest.
Best,
Vladimir
On Fri, Nov 14, 2008 at 7:28 PM, Vladimir Litvak
<[log in to unmask]> wrote:
> Dear Jerome,
>
> If you download the latest (current) version of EEGLAB, it contains a
> version of the fileio toolbox and a possibility to load files using
> fileio. One of the formats supported is SPM8 (and also SPM5). Perhaps
> it'd be a good idea to replace the fileio version there with the
> latest version that you can download from
> ftp://ftp.fcdonders.nl/pub/fieldtrip/modules/. Also I've experienced
> some error messages in EEGLAB with data loaded this way but this is
> something you should complain about to EEGLAB developers.
>
> Best,
>
> Vladimir
>
> On Fri, Nov 14, 2008 at 7:11 PM, Jérôme Courtemanche
> <[log in to unmask]> wrote:
>> Hi All,
>>
>> In the manual, it is mentioned that one can convert files from SPM8 to
>> EEGLAB. How to do so, precisely?
>>
>> Thanks
>>
>> Jerome
>>
>
|