Hi - you can't change this setting in the GUI, you can either edit
$FSLDIR/tcl/feat.tcl and search for the 2.8 setting, or fake the TR in
the GUI (but then you would need to adjust every other timing setting
including the model so that's a little dangerous).
Cheers.
On 26 Sep 2008, at 17:16, Binquan wang wrote:
> Dear FSL users:
>
> I need to do low pass filter when I processed the fmri data for some
> reason. There is low pass filter option in FEAT. But the parameter
> is fixed (2.8s). I just wonder if there is any way to change this
> parameter.
>
> Thank you.
>
> Binquan Wang
>
---------------------------------------------------------------------------
Stephen M. Smith, Professor of Biomedical Engineering
Associate Director, Oxford University FMRIB Centre
FMRIB, JR Hospital, Headington, Oxford OX3 9DU, UK
+44 (0) 1865 222726 (fax 222717)
[log in to unmask] http://www.fmrib.ox.ac.uk/~steve
---------------------------------------------------------------------------
|