Dear Guillaum,
Excuse me to bother you. I have found the problem in the attribtution of the
parameters. Still many thanks for your hints about contrast entrance.
I shall still ask for your help in the future..
Tao
----- Original Message -----
From: "jiang" <[log in to unmask]>
To: "Guillaume Flandin" <[log in to unmask]>; <[log in to unmask]>
Sent: Wednesday, July 02, 2008 8:01 PM
Subject: Re: [SPM] spm5 use
> Dear Guillaum,
>
> I'm doing my second level analysis, full factory
> I have entered all parameters a little like for the contraste for the
> 1st
> level.
> Then I have called similar commande
>
> spm_jobman('run', jobs), apprently it's not the good call, since I have
> gotten the error message in the attached file.
> Can I still begin with
>
> spm('Defaults','fMRI');
>
> and end with
>
> spm_jobman('run',jobs);
>
> Need I enter other argument to run fullfactor job ?
>
> Would you please help me.
> Sincerely thanks
> Tao
>
>
> ----- Original Message -----
> From: "Guillaume Flandin" <[log in to unmask]>
> To: <[log in to unmask]>
> Sent: Wednesday, June 18, 2008 7:08 PM
> Subject: Re: [SPM] spm5 use
>
>
>> Dear Tao,
>>
>> There is no "Multiple Contrasts" option like with "Multiple Conditions"
>> or
>> "Multiple Regressors" but this can easily be done with a script:
>>
>> % Define as many T-contrasts as you want
>> contrasts(1).name = 'Name_Contrast_1';
>> contrasts(1).convec = [1 0];
>> contrasts(2).name = 'Name_Contrast_2';
>> contrasts(2).convec = [0 1];
>>
>> % Specify and estimate new T-contrasts
>> spm('Defaults','fMRI');
>> clear jobs
>> jobs{1}.stats{1}.con.spmmat = cellstr('/path/to/SPM.mat');
>> for i=1:length(contrasts)
>> jobs{1}.stats{1}.con.consess{i}.tcon = contrasts(i);
>> end
>> spm_jobman('run',jobs);
>>
>> I hope this helps,
>> Guillaume.
>>
>> jiang wrote:
>>> Dear SPM5 users,
>>>
>>> I would like to know whether there is a method to enter the several T
>>> tests contrasts at the same time, a little like to enter multiconditions
>>> ?
>>> thank you for your help !
>>> Tao
>>
>> --
>> Guillaume Flandin, PhD
>> Wellcome Trust Centre for Neuroimaging
>> University College London
>> 12 Queen Square
>> London WC1N 3BG
>>
>>
>>
>
|