Thanks
The 'Clean up resonance application data' in FormatConverter has done
the trick. Interestingly the original assignment was set within the
project (i.e. not an import)
cheers guys
Marie
Quoting Wim Vranken <[log in to unmask]>:
> Hi Marie,
>
>> I checked that out and the project does seem to be pointing to
the
>> right .xml. I wonder if this wasn't the case more than just the
>> import would have gone awry, up until then the project seemed
well
>> behaved
>
> Seems indeed like it's the import. Are the assignments it is
reverting
> to ones that originally came from an import as well (i.e. from
CYANA
> files), or are they ones that you set in Analysis yourself?
>
> If they did come from an original import, it could be that the
> FormatConverter is picking up the 'old' information instead of the
new
> info, and using that to set the assignments.
>
> Before you import, try the following:
>
> 1. Open the FormatConverter
> 2. Go to process->Clean up resonance application data
> 3. Select cyana, then OK, then YES
> 4. Repeat 2. and 3. for dyana and xeasy, just in case.
>
> Then do the import.
>
> Hope that works,
>
> Wim
Marie Phelan
Joseph Black Building
Kings Buildings
West Mains Road
Edinburgh
EH9 3JJ
0131 6504704
--
The University of Edinburgh is a charitable body, registered in
Scotland, with registration number SC005336.
|