Dear Amit,
Guillaume responded to the same problem a few days ago:
> Please follow the indications given in this previous post:
> http://www.jiscmail.ac.uk/cgi-bin/webadmin?A2=ind0803&L=spm&P=1793
>
> Everyone using SPM5 with updates 1111 is advised to do the same, while
> waiting for the next official set of updates.
> Best regards,
> Guillaume.
Cheers,
Jan
Amit Etkin wrote:
> Hi all,
>
> I've been running into this problem quite frequently with results assessment
> in SPM5 and wondered whether anybody else had the experience or a solution.
> I've updated my SPM5 as of about 2 months ago....
>
> On about 20% of the times I hit the results button and chose an SPM.mat from
> some new folder (so far only for second level models and never yet for first
> level models) I get the specified contrasts for a completely different, but
> recently interrogated second level model (eg looking to assess A-B in
> controls, I get the contrasts specified for the A-B model for patients).
> Once the wrong contrasts come up, they remain there when you re-attempt to
> load them. If you click through, thinking that it's just the label that's
> different, you get a resulting map which looks somewhat like the original
> map you were going for, except that all of the significant voxels are red
> with no color-coding of significance. The only way I've gotten around this
> (and this certainly is a good way to duplicate effort and waste time) is to
> re-run my batch specification for that model and re-set up the contrasts of
> interest.
>
> any ideas????
>
> many thanks,
> Amit
>
--
Jan Gläscher, Ph.D. Div. Humanities & Social Sciences
+1 (626) 395-3898 (office) Caltech, Broad Center, M/C 114-96
+1 (626) 395-2000 (fax) 1200 California Blvd
[log in to unmask] Pasadena, CA 91125
|