Peter,
Why does the resolution need to be so high in your
estimation. These structures are well-seen in these
images. I have the same need, in essence, as Ying. I
need to measure volume of CSF in the brain. Any
thoughts out there?
Randy Benson
--- Peter Kochunov <[log in to unmask]> wrote:
> You would need your imaging resolution to be
> adjusted to ~200 microns in
> order to resolve these.
> pk
> ----- Original Message -----
> From: "Ying Chen" <[log in to unmask]>
> To: <[log in to unmask]>
> Sent: Monday, April 07, 2008 2:50 PM
> Subject: [FSL] dura mater
>
>
> > Hi,
> >
> > Is that possible to segment out the dura mater
> including falx cerebri and
> > tentorium cerebelli using T1 and T2 images?
> >
> > Thank you,
> > Ying
> >
>
____________________________________________________________________________________
You rock. That's why Blockbuster's offering you one month of Blockbuster Total Access, No Cost.