Hello,
Tim suggests checking that the figure of merit is not 0.0 (that is set in
the Peak List editor). And also check that in the Edit Spectra -->
Tolerances dialog that the shift weighting is 1. And check that the
experiment has a shift list. These are all remote possibilities but worth
double-checking. Otherwise send us the project without the spectra.
Wayne
On Tue, 8 Apr 2008, Vicky Higman wrote:
> Hi,
>
> I have just created a new resonance and have assigned it to two peaks. I
> noticed that the average shift was not corrected after making the second
> assignment. The Browse Resonances pop-up shows that there are two peaks
> and the Selected Peaks pop-up shows that these clearly have different
> chemical shifts. Closing and restarting Analysis didn't make a
> difference. I also tried recalculating the average shift in the
> Measurements pop-up. Interestingly, here this resonance only appears to
> be associated with one peak - despite the fact that both spectra
> involved belong to the same shift list.
> This is all illustrated in the attached screen shot - the resonance in
> question is [1065]{224}ARGC.
> Any idea what might be going on and why I am not able to get a correct
> average shift for this resonance? Or why only one peak is showing up in
> the measurements list?
>