Hi,
Are you using numbers after the -c command?
It should normally work like:
fslmeants -i all_FA -c 80 75 120 -o output.txt
If you do not give voxel coordinates after the -c then it
will not work properly either unless you use mm coordinates
with the --usemm flag.
I hope this helps.
All the best,
Mark
On 26 Feb 2008, at 21:23, S. Groppa wrote:
> Dear list,
>
> I apologize for this late and simple question, but I do not get
> smth...
>
> trying to get the voxel values from a 4D image by
>
> fslmeants -i all_FA -c -x -y z -o output.txt
>
> and output.txt has onyly 0s in it, fslview shows normal intensity
> values...
> I used --usemm with the same success...
>
> sure to simple, but i don't get it at this time.
>
> thanks a lot
> best wishes
> Sergiu
>
>
>
> --
> Mit freundlichen Grüßen
> S. Groppa
> mailto:[log in to unmask]
>
|