Hi Florian,m
the keyword is TRUSTED_REGION (see
http://www.mpimf-heidelberg.mpg.de/~kabsch/xds/html_doc/xds_parameters.html#TRUSTED_REGION=
and http://strucbio.biologie.uni-konstanz.de/xdswiki/index.php/XDS.INP
in XDSwiki).
HTH,
Kay
Florian Schmitzberger schrieb:
> Dear All,
>
> Is there a way to get XDS to include reflections in the far corners of
> diffraction images.
>
> XDS seems to take the high-resolution limit automatically from the edge
> of the images corresponding to the smallest radius from the center. In
> my case, with the keyword set to "INCLUDE_RESOLUTION_RANGE=50 0.0" it
> does not appear to include all reflections (those higher than 1.80 A
> resolution), although there are reflections to 1.60 A resolution in the
> corner of the diffraction images. I would like to include these
> reflections in the integration and processing. (Diffraction data was
> collected on a ADSC Quantum Q315r detector).
>
> Maybe I am missing something obvious.
>
> Thank you very much for any comments.
>
> Florian
--
Kay Diederichs http://strucbio.biologie.uni-konstanz.de
email: [log in to unmask] Tel +49 7531 88 4049 Fax 3183
Fachbereich Biologie, Universität Konstanz, Box M647, D-78457 Konstanz
|