Something has gone badly wrong with the initial affine registration. Would
it be possible to put the original image somewhere where I could download it
from to see if I can solve the problem? The affine registration is not as
robust as it was for older versions of SPM because it now only matches to
tissue probability images of GM, WM and CSF (there is no longer any
information for matching the scalp).
Bye for now,
-John
> Thank you kindly for your reply! Actually I am already specifying Native
> Space for the extraction process and the images still come out in the wrong
> coordinate space, as far as I know. Visual inspection shows that the images
> do not line up according to the input image. I will try to attach an image
> file showing the results of Check Registration. The image file can
> otherwise be found here:
>
> http://www.utdallas.edu/~okt061000/checkReg.png
>
> Thanks in advance!
>
> Best Regards,
> On
|